Coating delamination: finding the cause

When a coating lifts, blisters or peels, the useful question is where the failure runs and why. It can run along the interface or inside the coating or substrate; the interface may be contaminated; a process or the environment may have changed. Most investigations combine imaging, interface chemistry and, where a number is needed, a mechanical test.

What usually has to be established

  • Where the failure runs: along the interface, inside the coating or inside the substrate
  • What is on both fracture surfaces, compared with an intact reference
  • Whether a change in process, material or storage coincides with the failures

Measurements

Where an investigation often starts.

A typical sequence, not a prescription. The Field Agent adapts it to your sample, what you observed and the decision the result must support.

  1. SEM with EDXStart here

    Images both sides of the failure and shows which elements are on each, so you can see where the fracture runs and whether a foreign layer is present.

  2. X-ray photoelectron spectroscopyAlso useful

    Can detect thin contamination or oxide layers on an exposed failed interface that conventional SEM-EDX may miss. Vacuum compatibility and any cleaning or sputtering must be agreed.

  3. Cross-section preparationAlso useful

    A cross-section through an intact and a failing area shows the layer structure and where cracks start.

  4. Adhesion testingWhen a number is needed

    Compares adhesion using an appropriate test: pull-off measures a failure stress, while cross-cut gives a classification. These tests damage the tested area and do not establish the cause on their own.

What to have ready

  • Failed samples and intact references from the same batch
  • Coating and substrate materials, coating thickness and process history
  • When the failure appears: after deposition, curing, thermal cycling, humidity or use
  • Whether samples may be cut, coated or sputtered

Potential Dutch, Belgian and German facilities

160 facilities publish at least one of these measurements in Dresden, Berlin, Chemnitz, Enschede, Freiburg, Aachen, Amsterdam, Jena, Karlsruhe, Leipzig, Noordwijk, Stuttgart, Bayreuth, Bielefeld, Brussels, Clausthal-Zellerfeld, Eindhoven, Esslingen am Neckar, Freiberg, Greifswald, Halle (Saale), Hamburg, Hannover, Louvain-la-Neuve, Mainz, Mons, Namur, Rostock, Rudolstadt, Saarbrücken, Schmalkalden, Siegen, Wildau, Aalen, Aschaffenburg, Aschheim, Augsburg, Bad Homburg v. d. Höhe, Bamberg, Biberach, Brandenburg an der Havel, Braunschweig, Breda, Bremen, Bremerhaven, Darmstadt, Deggendorf, Delft, Denkendorf, Diepholz, Duisburg, Erfurt, Erlangen, Frankfurt (Oder), Fürth, Garching, Geesthacht, Gelsenkirchen, Genk, Ghent, Göttingen, Groningen, Gummersbach, Hamm, Hanau, Heilbronn, Ilmenau, Kaiserslautern, Kempten, Kleve, Koblenz, Köln, Krefeld, Lemgo, Liège, Lübeck, Magdeburg, Mannheim, Mittweida, Mülheim an der Ruhr, München, Nürnberg, Oberhausen, Oldenburg, Osnabrück, Paderborn, Petten, Pforzheim, Potsdam, Radeberg, Rüsselsheim am Main, Sankt Augustin, Schwäbisch Gmünd, Seraing, Solingen, Steinfurt, Stralsund, Tübingen, Utrecht, Vianen, Weimar, Weingarten, Weißandt-Gölzau, Wismar, Wolfenbüttel, Würzburg, Zwickau and Zwijnaarde.